Hubei Boshi Medical Instrument Co., Ltd.

 

Professional manufacturer of laser therapy device and body relax massager

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHeadache Device

White and Blue electrical impulses headache headband for Stress

Certification
Good quality Nasal Laser Light Therapy for sales
Good quality Nasal Laser Light Therapy for sales
I am so appriciated your services, expecting for next cooperation.

鈥斺 Travis Looi

Let me thank you very much for your kind help from time to time , which is unbelievable You are too great.

鈥斺 Bansi Hasija

Good customer service, I will introduce to my friends.

鈥斺 Joanna

I'm Online Chat Now

White and Blue electrical impulses headache headband for Stress

China White and Blue electrical impulses headache headband for Stress supplier

Large Image :  White and Blue electrical impulses headache headband for Stress

Product Details:

Place of Origin: China
Brand Name: BOSHI
Certification: CE
Model Number: BS-HT

Payment & Shipping Terms:

Minimum Order Quantity: 500 PCS
Price: negotiation
Packaging Details: 1PC/box,163脳170脳40 mm,30g
Delivery Time: 35 working days after received your payment for OEM order
Payment Terms: T/T or western Union,Paypal for sample
Supply Ability: 20,000pcs per month
Detailed Product Description
Product Name: Headache Treatment Instrument Electrical Specifications: 0 - 1000 惟(between 0 And 1000 Ohms)
Constant Amplitude Predefined Strength: Automatic Adjustment Maximum Current: 20 MA
Duration Impulse: 100 To 500 Microseconds Maximum Frequency: 150 HZ
Maximum Electricity Per Impulse: 5 尾C Maximum Time To Increase An Impulse: 5 Microseconds At 50% Of The Maximum

China Wholesale High Quality headache treatment instrument

 

 

Application

 

1. Well-being

2. Stress

3. Headaches,migraines and facial pain:

A.Tension headache

B. Migraine

C. Cluster headache

D. Frontal sinusitis, trigeminal neuralgias

(Idiopathic trigeminal neuralgia, symptomatic trigeminal neuralgia)

 

Characteristics

 

1. Accurate electrical impulses

2. Very comfortable

3. Efficient

4.Personalization

5.Super small and portable

 

 

 

 

Specification

 

ITEM

ITEM DESCRIPTION

Color

White and blue

Temperature

+10鈩 to +40鈩

Relative humidity

30% to 75%

Atmospheric pressure

700hPa to 1060hPa

Electrical Specifications

0 - 1000 Ω(between 0 and 1000 ohms)

Constant amplitude predefined Strength

Automatic adjustment

Maximum current

20 mA

Duration impulse

100 to 500 microseconds

Maximum frequency

150 HZ

Maximum electricity per impulse

5 βC

Maximum time to increase an impulse

5 microseconds at 50% of the maximum

Duration of programmes

20min

Number of programmes

3

Size

163×170×40 mm 

Weight

30g(excluding batteries)

 

 

Principle of treatment  

 

  1. Our Headache treatment generates very precise electrical impulses which permit selective stimulation of the nerve fibers.
  2. As the impulses are generated very slowly they are virtually imperceptible at the beginning of the session. Our Headache treatment measures the impedance of the skin and the stimulation coefficients of the nerve fibers.
  3. The device uses an electronic feedback mechanism to precisely adjust the characteristics of the impulses to the specific requirements of individual users.
  4. The treatment is consequently very comfortable as well as efficient and personalized.

 

SAFELY PRECAUTIONS,CONTRA-INDICATIONS AND SIDE EFFECTS

 

SAFELY PRECATIONS

1.Our Headache treatment is a medical device. It is suitable for children from the age of 8 upwards, but must always be used under adult supervision.

2.Do not use Our Headache treatment while driving.

3.Three per cent of the population are hypersensitive to electricity. Three individuals cannot tolerate the sensation caused by Our Headache treatment , and they are unable to carry out the treatment effectively.

4.Do not use Our Headache treatment any other areas apart from the forehead.

 

CONTER-INDICATIONS

1.Recent brain or facial trauma.

2.Skin abrasion on the forehead in the area of application of the electrode.

 

SIDE EFFECTS

The only significant side effect is a tendency towards sleepiness. This means that Our Headache treatment cannot be used when driving or when operating machinery.The skin on the forehead may become reddened where the electrode was placed at the end of the session.This is caused by stimulation of the circulation.Depending on the individual, this redness can last for a few minutes or more after the session.In very rare cases(less than 1 in 10.000)an allergy to the electrode gel can arise.A temporary rash gradually develops on the forehead.If this should occur,stop using Our Headache treatment and contact the manufacturer CEFALY Technology.The skin rash will gradually disappear within in a few days.The use of an anti-inflammatory cream can accelerate the disappearance of the rash.

 

DISCOUNTS

Large quantity enjoy more discounts,

Wholesalers/resellers or distributors are more than welcome. 
We will be happy to offer the best price with discount for multiple terms.

 

GUARANTEE & WARRANTY

100% Guarantee on all our laser therapy device, beauty and healthcare equipment! All machines comes with1 year full warranty, but honestly we will offer you LIFE TIME free online advise, help and the best after sale service even after years, so if you buy the machines from us, We will always be there for you!

 

Training

There are user manual and maintenance manual to guide you operating the machine

 

 

 

 

 

 

White and Blue electrical impulses headache headband for Stress

 

Contact Details
Hubei Boshi Medical Instrument Co., Ltd.

Contact Person: emilyhu

Tel: +8613554136979

Send your inquiry directly to us (0 / 3000)